| Detection of 2,4 D in Citrus Juice | Detection of 2,4 D in Citrus Juice. Fresh squeezed fruit juice, canned 100% fruit juice or frozen juice concentrates of citrus fruits. 2,4-Dichlorophenoxyacetic acid (2,4-D) RANGE OF 10 to 500 ppb in juice or 40 ppb to 2 ppm in juice concentrates. |
|---|
| Detection of Carbendazim in Milk | Detection of Carbendazim in Milk |
|---|
| Detection of Chlordane in Water | Detection of Chlordane in Water |
|---|
| Detection of Chlorpyrifos in Formulations | Detection of Chlorpyrifos in Formulations |
|---|
| Detection of DDT in Water | Detection of DDT in Water |
|---|
| Detection of part per Trillion Levels of 2 4 D in Drinking Water | Detection of part per Trillion Levels of 2,4-D in Drinking Water. Drinking water ANALYTES 2,4-D (2,4-dichlorophenoxyacetic acid) and related phenoxy acids LIMIT OF 70 ppt to 5 ppb (for 10 mL sample) DETECTION 7 ppt to 0.5 ppb (for 100 mL sample) MATERIALS 2,4-D RaPID Assay Kit and Sample Diluent Reagents. |
|---|
| Estimation of Atrazine and Simazine Concentrations | Estimation of Atrazine and Simazine Concentrations with RaPID Assay Kits. Water ANALYTES Simazine and atrazine LIMIT OF 0.1 ppb (ng/mL) DETECTION RANGE OF 0.1 to 3 ppb simazine and 0.1 to 5 ppb atrazine DETECTION MATERIALS Simazine RaPID Assay Kit Atrazine RaPID Assay Kit |
|---|
| Immunoassays for Environmental Contaminants in Food and Water | Immunoassays for Environmental Contaminants (Pesticides) in Food and Water. DAVID P. HERZOG I. ABSTRACT Immunoassays are one of the most powerful of all immunochemical techniques. |
|---|
| Procedure for Carbofuran RaPID Assay | Procedure for Carbofuran RaPID Assay Installation on the RPA-I. New RaPID Assay methods can be programmed by the operator into the RPA-I analyzer. This Technical Bulletin is a guide to the manual installation of the Carbofuran method on the RPA-I using the keypad. |
|---|
| Qualitative Determination of Atrazine in Water | Qualitative Determination of Atrazine in Water |
|---|
| Screening Method for 2,4-D and Silvex | Screening Method for 2,4-D and Silvex In TCLP Leachate. Leachate of solid or liquid waste as described in Toxicity Characteristic Leaching Procedure. 2,4-D and Silvex (2,4,5-TP) RANGE OF 1 to 50 ppm 2,4-D DETECTION 0.2 to 10 ppm Silvex |
|---|
| Use of 2,4-D RaPID Assay Kits | Use of 2,4-D RaPID Assay Kits for Semi-Quantitative Screening Consistent with SW-846 Method. The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. |