| Analysis of PCBs in Water | Analysis of PCBs in Water Using the DTECH Test System. PCB LIMIT OF DETECTION Color Card: 100 ppb (as aroclor 1254) DTECHTOR meter: 50 ppb (as aroclor 1254) BACKGROUND This application describes a field screening method for determining PCB concentrations in water. |
|---|
| AP Analysis of PCBs in Water | AP Analysis of PCBs in Water Using the EnviroGard Test System. Water ANALYTE PCB LIMIT OF DETECTION Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND This application describes a field screening method for determining PCB concentrations in water. |
|---|
| Detection of PCB on Gauze Wipes - hexane | Detection of PCB on Gauze Wipes using hexane. RANGE OF DETECTION: Low range: 5 to 100 mg per wipe, High range: 25 to 500 mg per wipe. |
|---|
| Detection of PCB on Gauze Wipes - Methanol | Detection of PCB on Gauze Wipes Using the RaPID Assay Test System using Methanol. PCB RANGE OF Low range: 5 to 100 mg per wipe DETECTION High range: 25 to 500 mg per wipe MATERIALS PCB RaPID Assay Test Kit (A00133) and Sample Diluent (A00136) PCB Wipe Sample Extraction Kit (A00137WA) |
|---|
| Detection of PCBs in Concrete EnSys | Detection of Polychlorinated Biphenyls (PCBs) in Concrete Using the EnSys Test System. Polychlorinated biphenyls (PCBs) RANGE OF DETECTION Aroclor 1254: 0.5 ppm Aroclor 1260: 0.5 ppm Aroclor 1248: 1.0 ppm Aroclor 1242: 2.0 ppm Aroclor 1232: 4.0 ppm Aroclor 1016: 4.0 ppm |
|---|
| Detection of PCBs in Concrete RaPID Assay | Detection of Polychlorinated Biphenyls (PCB's) in Concrete using the RaPID Assay kit. |
|---|
| Detection of PCBs in Water | Detection of PCBs in Water Using the EnSys Test Kit. PCB LIMIT OF DETECTION 1260: 50 ppb 1254: 50 ppb 1248: 100 ppb 1242: 200 ppb 1232: 400 ppb 1016: 400 ppb MATERIALS Ensys PCB 12 Test Kit, item # 7020301 Ensys PCB Soil Extraction Kit #7020300EA Clean tap or deionized water |
|---|
| Detection of PCBs in Wood | Detection of PCBs in Wood. Wood, reduced to fine shavings or sawdust, Polychlorinated biphenyls (PCB) LIMIT OF 2 ppm as Aroclor 1260 DETECTION MATERIALS PCB EnSys 12T Soil Test System Equipment: Tools for reducing wood to fine particles (refer to sample treatment section in document). |
|---|
| Procedure for EnSys | Procedure for EnSys Method Installation on the RPA-I |
|---|
| Procedure for PCB RaPID Assay Installation on the RPA-I | Procedure for PCB RaPID Assay Installation on the RPA-I. New RaPID Assay methods can be programmed by the operator into the RPA-I analyzer. COMMENTS This Technical Bulletin is a guide to the manual installation of the PCB method on the RPA-I using the keypad. |
|---|
| RaPID Assay PCB In Soil Application | RaPID Assay PCB In Soil Application. For detection of Polychlorinated Biphenyls (PCBs) (as Aroclor 1254) in soil. |
|---|
| Semi-Quantitative Analysis using the EnSys Methods | Semi-Quantitative Analysis using the EnSys Methods with the RPA-I |
|---|
| Use of PCB RaPID Assay Kits | Use of PCB RaPID Assay Kits for Semi-Quantitative Screening Consistant with SW-846 Method 4020 |
|---|
| Users Guide Sample Extraction Kit | Sample Extraction Kit Users Guide. This extraction kit is for use with the appropriate immunoassay test kit. Each Sample Extraction kit contains the materials necessary to process twelve (12) soil or wipe samples. |